Model No.: | S19 Pro+ Hyd 198Th | (Length*Width*Height: | 570*316*430MM |
---|---|---|---|
Net Weight, Kg: | 15.2kg | Hashrate, TH/s: | 198 ±3% |
Power Supply AC Input Voltage, Volt(2-1): | 342~418V | Two AC Input Wire: | 10A Per Wire |
Highlight: | S19 Pro+ Hyd Asic Bitcoin Miner,S19 XP Hydro Asic Bitcoin Miner,Antminer S19 XP Hydro |
NOTES
1. The ANTMINER S19 Pro+ Hyd. is recommended to be used simultaneously with the ANTSPACE HK3.
Specification:
Product Glance | |
Version | S19 Pro+ Hyd. |
Model No. | j0-10 |
Crypto Algorithm | SHA256 |
Hashrate, TH/s | 198 ±3% |
Power on wall @35°C, Watt(1-1) | 5445 ±5% |
Power efficiency on wall @35°C, J/TH(1-1) | 27.5 ±5% |
Detailed Characteristics | |
Power supply AC Input voltage, Volt(2-1) | 342~418 |
Power supply AC Input Frequency Range, Hz | 47~63 |
Power supply AC Input current, Amp(2-2) | 30 |
Hardware Configuration | |
Networking connection mode | RJ45 Ethernet 10/100M |
Miner Size (Length*Width*Height, w/o package),mm | 410*196*209 |
Miner Size (Length*Width*Height, with package),mm | 570*316*430 |
Net weight, kg | 15.2 |
Gross weight, kg | 17.5 |
Specification Details For ANTSPACE HK3 | |
Product Overview | |
Version | ANTSPACE HK3 |
Dimensions (L*W*H) (mm) | 6058*2438*2896 |
Miner Capacity | 210 units -S19 Hyd. Series miner |
Container Certification | China Classification Society Certification |
Safety Certification | North America/Standards:NFPA 79:2021,UL 508A:2018 R8.21, |
CSA C22.2 No. 14-18,ANSI/ISO 12100:2012 | |
EU/Standards:EN ISO 12100,EN 60204-1 | |
Operating Power(kW) | 1047~1050 |
PUE(Power Usage Effectiveness) | 1.022(Excluding cooling tower)/1.036(Including cooling tower) |
Input Voltage and Frequency | 415V±5% 60Hz(North America) |
400V±5% 50Hz(EU,Middle East) | |
Detailed Characteristics | |
Shipping Weight(T) | 8 |
Operating Weight (T) | 12 |
Main Switch of Power Distribution Cabinets(A) | 1200(North America) |
1250(EU,Middle East) | |
Rated Current(A) | 952 |
Standard Power(kW) | 1049 |
Maximum Power(kW) | 1050 |
Rated Current per Miner(A) | 10 |
Inlet Cable | The inlet cables can withstand high-voltage of above 600V, with the following requirements per phase: |
L1 single core cable 600kcMil(300mm²)x4 | |
L2 single core cable 600kcMil(300mm²)x4 | |
L3 single core cable 600kcMil(300mm²)x4 | |
N Single-core cable 600kcMil(300mm²)x4 | |
PE single-core cable 500kcMil(240mm²)x2 | |
Connection Interface(Cooling Tower) | DN125(GB/T 9119-2010 PN16 DN125) |
Connection Interface(Plate Heat Exchage Interface) | DN100(GB/T 9119-2010 PN16 DN100) |
Flow Rate(m³/h) | >85 |
Quantity of ANTSPACE powered by one 2500kVA Transformer | 2 |