Product Details:
|
Model No.: | S19 Pro+ Hyd 198Th | (Length*Width*Height: | 570*316*430MM |
---|---|---|---|
Net Weight, Kg: | 15.2kg | Hashrate, TH/s: | 198 ±3% |
Power Supply AC Input Voltage, Volt(2-1): | 342~418V | Two AC Input Wire: | 10A Per Wire |
Highlight: | 198T Antminer S19 Pro Hydro,184T Antminer Mining Machine,S19 Pro Hydro Miner |
184T 198T Antminer S19 Pro Hydro Miner Bitmain Antminer Mining Machine
Bitcoin Miner S19 Pro+ Hydro 184T 198t Bitmain Antminer Mining Machine Hydro miner
NOTES
1. The ANTMINER S19 Pro+ Hyd. is recommended to be used simultaneously with the ANTSPACE HK3.
Specification:
Product Glance |
|
Version |
S19 Pro+ Hyd. |
Model No. |
j0-10 |
Crypto Algorithm |
SHA256 |
Hashrate, TH/s |
198 ±3% |
Power on wall @35°C, Watt(1-1) |
5445 ±5% |
Power efficiency on wall @35°C, J/TH(1-1) |
27.5 ±5% |
Detailed Characteristics |
|
Power supply AC Input voltage, Volt(2-1) |
342~418 |
Power supply AC Input Frequency Range, Hz |
47~63 |
Power supply AC Input current, Amp(2-2) |
30 |
Hardware Configuration |
|
Networking connection mode |
RJ45 Ethernet 10/100M |
Miner Size (Length*Width*Height, w/o package),mm |
410*196*209 |
Miner Size (Length*Width*Height, with package),mm |
570*316*430 |
Net weight, kg |
15.2 |
Gross weight, kg |
17.5 |
Specification Details For ANTSPACE HK3 |
|
Product Overview |
|
Version |
ANTSPACE HK3 |
Dimensions (L*W*H) (mm) |
6058*2438*2896 |
Miner Capacity |
210 units -S19 Hyd. Series miner |
Container Certification |
China Classification Society Certification |
Safety Certification |
North America/Standards:NFPA 79:2021,UL 508A:2018 R8.21, |
CSA C22.2 No. 14-18,ANSI/ISO 12100:2012 |
|
EU/Standards:EN ISO 12100,EN 60204-1 |
|
Operating Power(kW) |
1047~1050 |
PUE(Power Usage Effectiveness) |
1.022(Excluding cooling tower)/1.036(Including cooling tower) |
Input Voltage and Frequency |
415V±5% 60Hz(North America) |
400V±5% 50Hz(EU,Middle East) |
|
Detailed Characteristics |
|
Shipping Weight(T) |
8 |
Operating Weight (T) |
12 |
Main Switch of Power Distribution Cabinets(A) |
1200(North America) |
1250(EU,Middle East) |
|
Rated Current(A) |
952 |
Standard Power(kW) |
1049 |
Maximum Power(kW) |
1050 |
Rated Current per Miner(A) |
10 |
Inlet Cable |
The inlet cables can withstand high-voltage of above 600V, with the following requirements per phase: |
L1 single core cable 600kcMil(300mm²)x4 |
|
L2 single core cable 600kcMil(300mm²)x4 |
|
L3 single core cable 600kcMil(300mm²)x4 |
|
N Single-core cable 600kcMil(300mm²)x4 |
|
PE single-core cable 500kcMil(240mm²)x2 |
|
Connection Interface(Cooling Tower) |
DN125(GB/T 9119-2010 PN16 DN125) |
Connection Interface(Plate Heat Exchage Interface) |
DN100(GB/T 9119-2010 PN16 DN100) |
Flow Rate(m³/h) |
>85 |
Quantity of ANTSPACE powered by one 2500kVA Transformer |
2 |
Contact Person: Nora Ji
Tel: 86-18123784965